BioScout

Medical Diagnosis via Breath Analysis


BioScout offers you the possibility to identify over 600 metabolites stored in our database. Studies have shown that BioScout is able to detect lung cancer, bacterial infections, COPD grades and much more.

Bacteria


Metabolites of bacteria and fungi

In an in vitro study IMS-chromatograms of different bacteria (Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pneumoniae, Streptococcus agalactiae, Haemophilus influenzae, Klebsiella pneumoniae, Escherichia coli, Serratia marcescens, Pseudomonas aeruginosa, Enterobacter cloacae) and a fungus, Candida albicans, were obtained. The selected bacteria and Candida albicans could be defined and distinguished by different metabolites.


Bronchial Carcinoma

Differentiation Bronchial Carcinoma / Healthy

Breath analysis by IMS can detect a discriminating combination of VOCs in patients with lung cancer. By pattern recognition without the need for chemical analysis of the underlying VOCs, IMS has the potential to facilitate lung cancer diagnosis.

COPD


Metabolites related to COPD

Within a clinical study the exhaled breath of persons suffering with COPD (with and without lung cancer) and healthy volunteers was investigated using an Ion Mobility Spectrometer coupled to a Multi-Capillary Column without any pre-separation or pre-enrichment. A single analyte was able to separate the two groups of healthy persons and those suffering from COPD with and without lung cancer. The sensitivity obtained was 60%, the specificity 91%, the positive predictive value 95%. The peak was characterised as cyclohexanone (CAS 108-94-1). Thus, a concentration of cyclohexanone above the threshold could be seen as an indicator for COPD. The identity of the peak used for separation of the two groups mustbe validated with a greater population and external standards. Additional studies with a higher population and parallel measurements using GC/MSD will support the identification further.


Medication Control

Time series of metabolites related to pharmaceuticals

Metabolites in human breath were found relatable to pharmaceuticals. Time series are obtained by an investigation of single analytes directly.

Tumor Type

Tumor metabolites

Ion mobility spectrometry coupled to a multi capillary column (MCC/IMS) is currently evaluated for the analysis of exhaled breath to diagnose lung cancer. The origin of specific volatile organic compounds (VOC) detected in patients with non-small-cell lung cancer (NSCLC) still remains unknown.

We wondered whether there are different VOCs in bronchi close to the tumour and the lung of a cancer patient in general.

10 patients with histologically proven peripheral NSCLC were included in the study. During flexible bronchoscopy a catheter connected to an MCC/IMS was introduced through the working channel of the bronchoscope. Gas samples were aspirated from the tumour bearing side and the contralateral lung.



There were no adverse events. In the measured data set 61 common peaks could be detected. Four peak intensities were significantly different between the tumour bearing site and the unaffected side lung. Among these peaks, three peaks were significantly higher and one was lower on the tumour site. Two peaks showed a difference between both lungs only for adenocarcinoma and one particularly in patients with squamous cell and undifferentiated NSCLC.

Some VOCs are present in a different concentration in the air near by a NSCLC than in a distance of the tumour. Therefore these VOCs may reflect metabolic products of the tumour.
Documentation :

Demande en ligne




 
MEDIMA SANTE sprl
Showroom et entité technico-commerciale :
Rue de la Drève, 62 • 4560 Clavier Belgique • Tél. : +32 (0) 473 21 01 70 • Fax : +32 (0) 86 21 46 26 • Gérant: Christian Mathonet